DS - DSF

Submersible pump with semi-open impeller with cast iron shim and anti-clogging filters, supplied as standard with the thermal protector and double mechanical seal with oil chamber. Suitable for pumping clear water and rainwater. Read more

Features

Possibility to use in fixed and mobile installations

Possibility to use in fixed and mobile installations

Non-clogging filter

Non-clogging filter

Adjustment semi- open impeller

Adjustment semi- open impeller

PZH
Submersible pump with semi-open impeller with cast iron shim and anti-clogging filters that provide high efficiency.
The thermo protector supplied as standard in the range and the double mechanical seal with oil chamber prevent damage from dry running of the pump.
For further technical information see the Databook

• Drainage
• Domestic irrigation (e.g. gardens)
• Pumping of rainwater and clear water

Technical data

Flow rate up to 84 m³/h
Total head up to 43 m
Max. temperature of the liquid +40°C
Poles 2
Max. solids passage 5 mm (50DS)
6 mm (65DS) (40DSF 1.5, 1.9 kW)
7 mm (80DS) (40DSF 6 kW)
8 mm (100DS)
Insulation class F for DS
H for DSF
Protection degree IP68
Voltage Three-phase 3~380-415±10% (DS)
Single-phase 1~230±10% (DSF)
Three-phase 3~400/690±10% (DSF)
Max. immersion up to 1.5kW:
3 m with 6 m cable
over 1.5kW:
7 m with 10 m cable
Max. length of fibres 50 mm

Materials

Pump body Cast iron
Impeller Cast iron
Shaft Stainless steel AISI 403 (EN 1.4006) (DS)
Stainless steel AISI 420B (EN 1.4028) (DSF)
Mechanical seal Impeller side: Silicon Carbide/NBR
Motor side: Carbon/Ceramic/NBR (6 kW and above for DSF)

How can I adjust the float switch in order to avoid problems when starting or stopping?

If the pump is fitted with a float switch, the latter must have enough room to move freely, so that it can switch and ensure a proper pump operation.
Please follow the directions provided in the instruction manual when the installation requires float switches that are fixed to the tank and are driven by a distribution board.

What is the minimum amount of liquid that the pump must be submerged in?

Strictly follow the directions provided in the instruction manual.

What should the dimensions of the handhole where I’m inserting the pump be?

It depends on the pump’s type and model.
Strictly follow the directions provided in the instruction manual.