BEST 2-5

Submersible pump made entirely of AISI 304 stainless steel, with double mechanical seal in oil chamber, also available with float switch. Possibility of fixed or mobile installation and suitable for domestic applications and large industrial drainage installations. Read more

Features

Possibility to use in fixed and mobile installations

Possibility to use in fixed and mobile installations

PZH
Submersible pump entirely in AISI 304 stainless steel, with double mechanical seal in oil chamber.
Practical and easy to use, BEST 2-5 electric pumps are also available with float, thus increasing their versatility of use.
For further technical information see the Databook

• Handling of seepage water
• Emptying of basements, garages, cellars
• Drainage of small and medium-sized construction sites

Technical data

Flow rate from 1.2 to 21.6 m³/h
Total head from 2.9 to 18.4 m
Max. temperature of the liquid +35°C
Poles 2
Max. solids passage 10 mm
Insulation class F
Protection degree IP68
Voltage Single-phase 1~230V ±10%
Three-phase 3~400 ±10%
Max. immersion 7 m with 10 m cable

Materials

Pump body Stainless steel AISI 304 (EN 1.4301)
Impeller Stainless steel AISI 304 (EN 1.4301)
Shaft Stainless steel AISI 303 (EN 1.4305) (part in contact with liquid)
Mechanical seal upper part in Carbon/Ceramic/NBR (motor side)
lower part in Silicon Carbide/NBR (pump side)

Can I extend/replace the power cord without causing technical problems or affecting the warranty?

Yes, anyhow this operation has to be carried out by a specialised technician or at an authorised EBARA Service Centre. This avoids improper connections that can adversely affect the pump’s correct operation and/or the safety of the installation.

What is the minimum amount of liquid that the pump must be submerged in?

Strictly follow the directions provided in the instruction manual.

How can I adjust the float switch in order to avoid problems when starting or stopping?

If the pump is fitted with a float switch, the latter must have enough room to move freely, so that it can switch and ensure a proper pump operation.
Please follow the directions provided in the instruction manual when the installation requires float switches that are fixed to the tank and are driven by a distribution board.

What should the dimensions of the handhole where I’m inserting the pump be?

It depends on the pump’s type and model.
Strictly follow the directions provided in the instruction manual.


More details
Do you need more information about this product? Send us your request.

Contact us

* Required